Backflow Preventer Testing in Poway

Each preventer type gets the test procedure written for it.

Reduced pressure assemblies, double checks, pressure vacuum breakers and spill-resistant vacuum breakers are each tested differently. We identify yours, run its procedure, and explain the results if you'd like. The price depends on size, not type.

  • Price$105 flat
  • TimeUnder an hour
  • SchedulingSame week
  • FilingIncluded

Pricing

Backflow sizeFlat fee per backflow
Under 4"$105
4" and larger$175

Includes the test and filing with your water district. No hidden fees.

Questions before you book? Call us. We're happy to explain.

Types we work on

  • Fire line detector assemblies (DCDA, RPDA)
  • Pressure vacuum breakers (PVB)
  • Spill-resistant vacuum breakers (SVB)
  • Reduced pressure (RP or RPZ) assemblies
  • Double check valve assemblies

Testing reduced pressure (RP) assemblies

A reduced pressure principle assembly, often called an RP or RPZ, is the device used on high-hazard connections. It has two check valves with a relief valve between them. If either check leaks, the relief valve opens and dumps water out of the bottom instead of letting it travel backward.

Testing an RP takes a few more steps than other devices. The tester checks the point where the relief valve starts to open, then checks the first check valve and the second check valve to make sure each one holds tight.

Because RPs protect against the worst kinds of contamination, districts watch them closely. A relief valve that drips during normal use is a common sign that the first check is fouled or worn. We'll point that out even if the device squeaks by on test day, since it usually means a failure is coming.

Testing double check valve assemblies

Double check valve assemblies use two check valves back to back. There's no relief valve, so they're used where the hazard is lower, such as many fire sprinkler services and some landscape and building lines.

Testing one means checking each valve separately. The tester closes the shutoffs, connects the gauge to the test cocks and confirms both checks hold.

These devices are often in underground boxes or vaults. If yours tends to collect water, mud or critters, mention it when you schedule. We'll bring what we need to clear it out so the test can go ahead on the same trip.

Vacuum breakers on irrigation lines

PVBs and SVBs are common on residential and commercial irrigation. They're the above-ground devices with a bonnet on top, usually near the sprinkler valves. Their job is to stop water from being siphoned back out of the sprinkler lines when pressure drops on the supply side.

The test checks two things: that the air inlet opens and that the check valve holds tight. It's quick, and these are often the easiest devices to reach.

Placement matters with these. They need to be above the highest downstream sprinkler or outlet to work as designed. If yours looks too low, we'll tell you, because a device can pass its readings and still be installed wrong.

Fire line and detector assemblies

Fire sprinkler services usually have a detector assembly, either a double check type (DCDA) or a reduced pressure type (RPDA). A small bypass line with a meter runs alongside the main device to show whether water is moving through the fire line.

Both the main assembly and the bypass get tested. Since most fire line devices are 4 inches or bigger, they fall in our $175 per device tier.

Because shutting a fire line valve can set off alarms or affect monitoring, we talk with you or your building manager before we start. If an alarm company needs to be notified, we'll let you know ahead of time so the test goes smoothly.

Figuring out which type you have

Most devices have the manufacturer's name and model cast into the body or printed on a tag. The model number usually tells you the type. If you can't read it, shape helps: an RP has a relief valve port on the bottom between two checks, a double check has two check covers and no relief port, and a PVB or SVB has a bonnet on top with a single check.

You don't need to know before you book. A photo is enough for us to tell, and the tester confirms it on site before starting.

How age affects results

Device type matters less than condition when it comes to passing. A ten-year-old double check that has been rebuilt on schedule can pass easily, while a three-year-old RP on a line full of debris can fail.

That said, older devices do fail more often as rubber ages and parts wear. If yours is old enough that parts are getting hard to find, we'll mention it, so replacement can be planned instead of rushed.

Don't know which one you have?

A quick photo is usually enough for us to tell. Or read our comparison guide.

Questions

Which type is most common on homes?

On sprinkler lines it's usually a PVB or double check. On the main line it's often a double check or RP.

Is an RPZ the same as an RP?

Yes. Both names refer to a reduced pressure principle assembly.

Do all types cost the same to test?

Pricing goes by size, not type: $105 for devices under 4 inches and $175 for 4 inches and up.

Can you test a device installed underground?

Yes. Let us know when you book if the vault fills with water or dirt so we come ready to clear it.

Is the price different for an RP?

No. We charge by size: $105 under 4 inches, $175 for 4 inches and larger.

Do fire line devices need the fire department?

Usually not for the test itself, but we coordinate with you first since closing valves can trigger alarms.

Why Poway customers choose us

We focus on backflow prevention, so we know the devices, the test procedures and what your water district expects to see. Our testers are certified, our gauges are kept in calibration, and we'll explain what we find in plain terms.

You'll always know the price before work begins. Testing is $105 per device under 4 inches and $175 for 4 inches and larger, and other work is quoted free. Our office answers seven days a week, 6am to midnight, and emergency calls are answered 24/7.

Many of the people who call us have never dealt with a backflow device before, and that's fine. We'll tell you where the device is, what the test involves, and what the readings mean, without the jargon. If a repair or replacement comes up, you'll get the reasons and the price in writing so you can decide on your own schedule. Nothing gets done without your okay.